Instructions
Plans must be prepared and signed by a state certified individual and include their certification number. Plans must be prepared in such a manner that the installer can read and follow them in order to install the system properly. Construction shall not commence until the plans have been approved. Uploaded designs must be legible.
Materials
- Schedule, material, and size of pipe to be used
- Septic tank manufacturer, size of tank, and maximum burial depth of tank
- Type of gravel to be used (3/4" minimum to 2 1/2" maximum)
- Type of separation material to be used (straw or fabric)
- Type of chambers to be used: manufacturer, model, size
Details
- Shall be drawn to scale (not to exceed 1 in = 30 ft), indicate scale used
- Must include risers, clean-outs, and sampling ports as required by rule
- Location and distance from water supply lines
- Location of private water source including 200' protection zone
- Location of 100' protection zone must be indicated on a County Plat showing property line, water source location and 100' in all directions with no source of contamination
- Locations and distance of any watercourse, lake, pond, or reservoir within 200'
- Location and distance from curtain drains
- Location and distance of property lines
- Location of raodways, driveways, and parking areas
- Location of easements or right-of-ways affecting property
- Location and distance from and down slope, cut bank, or top of embankment
- Location of soil exploration and perc. test holes
- Location and size of replacement area
- Distance from any building foundation
- Distance between trenches and length of distribution lines
- Slope of building sewer (must not be less than 1/4" per foot). Includes pipe from building to tank, and tank to drainfield.
- Slope of distribution laterals (should be level)
- If required onsite assessment form, relative evaluations MUST be provided. Indicate the original grade and trench bottom for both ends of each distribution lateral.
Cross Section of Trench
- Depth and width of excavation
- Depth of pipe or chamber inlet
- Depth of filter material
- Separation material
- Depth of backfill
- Maximum DIG depth of trenches
Installation Instructions
- Please provide detailed installation instructions to enable the owner or third party contractor to install the system. Examples: how to enter/exit chamber end caps, orientation of perforated pipe, etc.